Interference mitigation parameters and typical values
Technique
Parameter
Value
Comments and references
ANF
Pole contraction factor, kα
[0.7,0.9]
For swept interference (Borio, O’Driscoll, and Fortuny, 2012; Qin, Dovis, et al., 2019; Qin, Troglia Gamba, et al., 2019; Troglia Gamba et al., 2012; Wendel et al., 2016)
[0.9,0.98]
For CWI (Calmettes et al., 2001; Raasakka & Orejas, 2014; Troglia Gamba et al., 2012)
Adaptation step, δ
(Calmettes et al., 2001; Qin et al., 2019; Wendel et al., 2016)
PB
Decision Threshold, Th
αTσ
Require noise floor estimation (Bastide, Chatre et al., 2004; Raimondi et al., 2008; Rugamer et al., 2017; Wang et al., 2010)
quantization level
Noise floor estimated by the AGC (Bastide, Macabiau et al., 2003; Borio & Cano, 2013; Hegarty et al., 2000)