TABLE 2

Spectral coefficients of oscillators as used during data analysis: *derived from manufacturer’s data, individually determined by Jain et al. (2021), according to Brown and Hwang (2012)

Oscillatorh0h–1h–2
Vremya VCH-1006*2 · 10–242 · 10–29
Microsemi MAC8 · 10–227 · 10–253 · 10–29
TCXO (low quality)2 · 10–197 · 10–212 · 10–20